Avery Weigh-Tronix 220 Tank Mount Stainless Steel Compression Load Cell

Avery Weigh-Tronix 220 Tank Mount Stainless Steel Compression Load Cell

Avery Weigh-Tronix 220 is specifically designed for the support of tanks, silos, and hoppers. It is ideal for indoor or outdoor process control applications when high accuracy weighing is required. The 220 tank mount load cell is designed to support a uniformly distributed load

RFQ

Call: (919) 776-7737

Avery Weigh-Tronix 220 Tank Mount 0.1% SERIES - STAINLESS STEEL COMPRESSION LOAD CELL WITH STAND

Legal for Trade CC# 00-067, Class IIIL 10,000 divisions
The 220 Tank Mount 0.1% series includes: a 1000-ohm full-bridge compression load cell mounted in a stainless steel wash-through stand. The 5,000 kg unit has a 16-ft cable, the 10,000 kg and 20,000 kg units have a 32-ft cable and the 30,000 kg unit has a 64-ft cable attached to each cell. When combined with junction box, interface cable and indicator and properly installed, an overall accuracy of at least .1% should be attainable.

Part Number
Capacity
Sensitivity
Ship Wt (lbs
55521-0012
11,000 lb
2 mV/V
37
55521-0020
22,000 lb
2 mV/V
37
55521-0038
44,000 lb
2 mV/V
50
55521-0046
66,000 lb
2 mV/V
50

ALSO AVAILABLE IN A KIT

Important Note: "Kit Gross Weight Capacity" is given as a guide to help the designer. It is the designers responsibility to insure that the Weigh Bar® / load cell capacity is suitable for the application. Consideration may need to be made to avoid overloading caused by wind effects, ground movement, or other dynamic effects such as mixers, vibrators, or shock loading. Each of the kits is available in either three or four load sensor models. All kits include a Model JBIT stainless steel NEMA 4X junction box and 60 feet of standard interface cable.

220 Tank Mount 0.1% SERIES KIT STAINLESS STEEL COMPRESSION LOAD CELL W/ MOUNT
Legal for Trade CC# 00-067, Class IIIL 10,000 divisions
The 220 Tank Mount 0.1% series includes: a 1000-ohm full-bridge compression load cell mounted in a stainless steel stand. The 5,000 kg unit has a 16-ft cable, the 10,000 kg and 20,000 kg units have a 32-ft cable and the 30,000 kg unit has a 64-ft cable attached to each cell.

(3) Cell Kit
Part Number
Cell Capacity (lbs)
Kit Gross Wt Capacity (lbs)
Sensitivity
Ship Wt (lbs)
53378-0011
11,000
33,000
2 mV/V
110
53378-0029
22,000
66,000
2 mV/V
110
53378-0037
44,000
132,000
2 mV/V
155
53378-0045
66,000
198,000
2 mV/V
155
(4) Cell Kit
53379-0010
11,000
44,000
2 mV/V
145
53379-0028
22,000
88,000
2 mV/V
145
53379-0036
44,000
176,000
2 mV/V
200
53379-0044
66,000
264,000
2 mV/V
200